Case Study      Connector Housing · Germany

Parameter Specification
Process Injection Molding + Insert Molding
Material PA66
Application Plastic Housings for Terminal-Based Electrical Connectors
Housing Structure Custom Terminal Cavities and Locking Features
Insert Type Brass Terminals
Critical Dimensions Terminal Position, Cavity Dimensions, Mating Interfaces
Electrical Requirements Electrical Insulation

Key Challenges and How We Solved Them

We helped a German industrial electronics manufacturer resolve terminal misalignment and cracking in their custom PA66 connector housings. By optimizing the insert molding process, we achieved precise metal positioning and strict dimensional consistency for reliable assembly.

The Challenge


  • Terminal misalignment during insert molding.

  • Stress-related cracking in finished parts.

  • Dimensional instability due to shrinkage and warpage.

  • Flash formation around metal terminals.
  • Our Solutions


  • Redesigned insert locator slots and added support ribs to securely lock terminals.

  • Replaced sharp corners with fillets and lowered injection pressure to eliminate stress cracking.

  • Modified gate sizes and adjusted holding pressure to control shrinkage and warpage.

  • Added taper to shut-off surfaces and improved mold fit to prevent terminal flash.
  • Production Photos & Process Records

    Connector Housings Mold Making
    Connector Housings Production
    Quality Inspection Connector Housings
    High Volume Connector Housings
    Note: This project is covered by a confidentiality agreement. Certain details have been anonymized, and the publicly displayed information has been approved by the client.

    Start Your Custom Project

    Have a similar part in mind? Share your drawings or specs, and our engineers will respond within 24 hours with a feasibility review and quote.